Technology Unit

Icon
Ethane/Ethylene Separator
Icon
Linde Steam Cracking
Short Name
Ethane/Ethene Separation
Description

Open Loop C2 Fractionation System:

C2 Splitter overhead product is heated then pressurized in the 3rd stage of C2 ref. compressor.
Further compression in the 4th stage and the balance stream is cooled against the cold overhead vapours and condensed in the reboiler of the C2 splitter:

  • mainly subcooled and used as a reflux.
  • others are condensed against propylene refrigerant and stored in Ethylene Collecting Drum.

Temperature levels of ethylene refrigerant:

  • Low pressure (LP) C2 refrigeration:  -101°C
  • Medium pressure (MP) C2 refrigeration:  -80°C
  • High pressure (HP) C2 refrigeration: -57°C

Propylene Refrigerant Cycle:

  • Intermediate temperature range between cooling water and ethylene refrigerant.
  • Temperature levels of propylene refrigerant :
    • Low pressure (LP) C3 refrigeration: -38°C
    • Medium pressure (MP) C2 refrigeration: -20°C
    • High pressure (HP) C3 refrigeration: +10°C

Source: Y.A. Sastry & Uday Krishna Dy, DUAL FEED CRACKER UNIT & ASSOCIATED UNIT, ONGC Petro additions Limited (OPaL), Uploaded on 28th Jan 2018 on SCRIBD.

Link
System Info

Updated by
UserPic  Kokel, Nicolas
Updated
5/8/2024 9:12 AM
Added
4/27/2024 2:59 PM
  Image
ONGC Petro additions Limited (OPaL) www.scribd.com/presentation/370150587/Duel-Feed-Cracker-Unit-Associated-Unit